Orientation Drop Test
Under the condition of starting the machine, the test sample falls from 2 ± 0.05m (2.8 screens and below) / 1.5 ± 0.05m (5.0 screens and below) 1.2 ± 0.05m (5.0 screens and above) to the surface of marble floor in a directional manner, two falls for each of the six sides and four corners, a total of 20 falls; after the test, except for the scratches or dents within 2 * 2mm, the function Appearance and assembly inspection shall be normal.
Repeated Drop test
The test sample shall be put into the roller with the rotation frequency of 10 times / min at the height of 0.6m under the condition of starting the machine for 200 turns (400 times); after the test, except for the scratch, bruise or dent within 2 * 2mm allowed on the surface, the function, appearance and assembly inspection shall be normal. 1.1m height for function machine.
Mechanical Plug and Pull Test
The function, appearance and assembly test of I / O port and plug shall be normal after 10000 times of plugging and unplugging under the shutdown state of test sample.
Key life
Under the condition of starting the machine, the test sample shall be operated at the speed of 40-60 times / min, with 100000 times of on-off key, 50000 times of side volume key and 100000 times of other keys, and the function, appearance and assembly inspection shall be normal.
Marking Life test
The function, appearance and assembly test of the test sample shall be normal after 100 thousand times of drawing a circle in the center of the screen and a straight line around the edge with a force of 150 ± 5g when the test sample is started and input by hand.
High and Low Temperature Test
High temperature working test, the function, appearance and assembly of the test sample shall be normal after 12 hours of high temperature test (55 ℃ ± 3 ℃) and 2 hours of normal temperature recovery.Low temperature working tes,after 12 hours of low temperature test at (- 30 ℃ ± 3 ℃) and 2 hours of recovery at room temperature, the test sample shall be tested for normal function, appearance and assembly.
Salt Spray Test
After the following salt spray test, the function, appearance and assembly of the test prototype shall be normal without discoloration, discoloration, crazing, blistering, falling off and other abnormalities.
Waterproof Test
The sample was immersed in 1.8m deep water column for 30 minutes without water. After the test, the mobile phone function was normal.
Ball Impact Test
The function and appearance of the steel ball passing through the center of the display / touch screen and the four corner surfaces (0.2j impact energy drop height 35cm, weight 64g) once respectively shall be normal.